Energy & Behaviour Archives Page 2 of 6 University of Southampton Blogs
Typically, counter-Ip ECCD leads to faster penetration for higher RMP currents. This section presents TM1 simulations aimed at predicting the sensitivity of the threshold of RMP current, necessary to trigger the 11/3 magnetic island, with respect to the amplitude of the counter-Ip ECCD current. The profile of ECCD source current density is look at the original shown in dashed curves in (a).
The periodic and transient power load exerted on the plasma-facing components by these ELMs is a critical concern for the integrity and lifespan of such components in future high-power H-mode devices, including the International Tokamak Experimental Reactor (ITER) . These findings indicate that counter-Ip ECCD holds promise as a potential actuator to facilitate RMP-driven ELM suppression if it can be injected in the edge pedestal region. Dependence of RMP penetration threshold on counter-Ip ECCD source current in terms of 2D contour plot of (a) 11/3 magnetic island width, and (b) pedestal pressure versus RMP current and ICD.
2D contour plot of the TM1 simulated (a) 11/3 magnetic island width, (b) 10/3 magnetic island width, (c) the pedestal pressure, and (d) the ECCD driven efficiency versus normalized pedestal density pump versus ψds and ICD. The instantaneous deposition width Δξ is scanned to investigate the sensitivity of the stabilizing/destabilizing effect on the width of ECCD current along the helical angle, as illustrated in figure 7. In the simulations, only the 11/3 component and its harmonics (22/6, 33/9, …) are included, unless stated otherwise. Due to the spatial diffusion of fast electrons, the EC current density depends on both the wave deposition region and the transport of the fast electrons generated by the EC wave. Tokamak discharges operating in high-confinement mode (H-mode) exhibit intermittent bursts of heat and particle transport originating from the outer regions of the plasma, known as type-I edge-localized modes (ELMs) .
Meanwhile, more counter-Ip ECCD destabilizes the magnetic island to larger width and leads to more reduction in pedestal pressure to sustain ELM suppression. This outcome is reasonable since the counter-Ip ECCD inside the 11/3 rational surface still decreases the radial gradient of plasma current density at the 11/3 surface. 2D contour plot of the simulated (a) 11/3 magnetic island width and (b) pedestal pressure by scanning ICD and the wave deposition width Δξ along the helical angle. 2D contour plot of the simulated (a) 11/3 magnetic island width and (b) pedestal pressure by scanning ICD and the center of the ECCD along the helical angle ξ0. In (a) and (c), radial profiles of the 0/0 component of the ECCD source current density (black) and the driven current density (red or blue) are shown.